Specifications:

Power:

 

Current consumption:

 

Battery life:

 

Maximum altitude:

 

Altitude resolution:

 

 

 

Analog to Digital Converter:

 

Calibration accuracy:

 

Measurement precision:

 

Sample rate:

 

Operational temperature:

 

4V – 16V, nominal 12V A23 battery

30 hours

100' AGL

100,000' MSL

< 2' to 52,000' MSL

< 5' to 72,000' MSL

24 bit Sigma Delta

+/- 0.05% typical

20 samples per second

-40C to +85C (-40F to +185F)

+/- (0.1% reading + 1 foot) typical

Launch detect:

 

1.5 ma

1' up to 38,000' MSL

Dimensions:

 

Weight:

 

0.56 oz. including battery

2.75"L x 0.55"W x 0.62"H